100 CFM Refrigerated Air Dryers
|
MSRP: $2,838.00
Price: $1,941.00
You Save: $897.00 (32%)
Item Number: F-100
Manufacturer: WorldAir
Manufacturer Part No: F100
|
Refrigerant System
|
• All Stainless Steel Heat Exchanger Combining both Air-to-Air and Refrigerant-to-Air Circuitry
|
|
• Highly Efficient Hermetic Compressor
|
|
• Thermally Protected
|
|
• Copper Tube and Aluminum Fin Condenser
|
|
• Quick Response Expansion Valve
|
|
• All Electrical Components Easily Accessible
|
|
• Universal CFC Free R-134A Refrigerant
|
Air System
|
• Enhanced Condensate Separator Includes 40 Micron Sintered Bronze Filtration
|
|
• Exiting Air is Reheated to Eliminate Downstream Condensation
|
|
• Maximum Pressure Drop Less than 4 psi
|
|
• Electronic Timer Drain (F-75 and F-100)
|
|
• Zero Loss Drain (F-125 thru F-150)
|
Instrumentation
|
• Power On/Off Switch and Integrated Light
|
|
• Dew Point Indicator Gauge
|
Cabinet
|
• New Compact Cabinet Design Incorporates Improved Accessibility and Function
|
|
• Powder Coated Textured Paint Finish
|
|
• Heavy Duty Metal Construction
|
Electrical
|
• Lowest Power Consumption
|
|
• Several Available Voltages:
1. 115/1/60 or 100/1/50
2. 208-230/1/60 or 200-240/1/50
|
|
• 6' Power Cord
|
Warranty
|
• 2 Year Compressor Warranty
|
|
• 5 Year Heat Exchanger Warranty
|
Air Flow Ratings
Air dryer rated flows are based upon design conditions of 100°F inlet, 100 psig and 100°F ambient. If these conditions vary, the rated flows will vary in accordance with the following general rules and tables.
|
As Inlet AIr Temperature increases, Flow Capacity will decrease:
|
|
Inlet AIr Temperature
|
90°F
|
95°F
|
100°F
|
110°F
|
120°F
|
|
Flow Capacity Multiplier
|
1.23
|
1.13
|
1.00
|
0.83
|
0.69
|
|
As Air Line Pressure increases, Flow Capacity will increase:
|
|
Air Line Pressure
|
60 psig
|
80 psig
|
100 psig
|
120 psig
|
150 psig
|
|
Flow Capacity Multiplier
|
.88
|
.95
|
1.00
|
1.04
|
1.08
|
|
As Ambient Air Temperature increases, Flow Capacity will decrease:
|
|
Ambient Air Temperature
|
80°F
|
90°F
|
100°F
|
110°F
|
|
Flow Capacity Multiplier
|
1.14
|
1.07
|
1.00
|
.92
|
|
As the Dew Point increases, Flow Capacity will increase: If design conditions (100ºF, 100 psig, 100ºF ambient) remain the same, but a higher dew point is acceptable, the Flow Capacity will increase approximately in accordance with the following multipliers:
|
|
Dew Point
|
39°F
|
45°F
|
50°F
|
|
Flow Capacity Multiplier
|
1.05
|
1.15
|
1.20
|
Moisture Removal Data
|
Temp at Receiver Tank
|
System Tank
|
Lbs. Condensed Per 100 CFM
|
Lbs. Per 8 Hr. Shift
|
Gallons Per 8 Hr. Shift
|
|
120
|
70
|
.05613
|
26.94
|
3.23
|
|
100
|
70
|
.02455
|
11.78
|
1.41
|
|
90
|
70
|
.01399
|
6.718
|
.81
|
|
80
|
70
|
.005965
|
.005965
|
.34
|
|
120
|
50
|
.06386
|
.06386
|
3.67
|
|
100
|
50
|
.03227
|
15.49
|
1.86
|
|
90
|
50
|
.02172
|
10.43
|
1.25
|
|
80
|
50
|
.01369
|
6.571
|
.79
|
|
120
|
35
|
.06714
|
32.23
|
3.86
|
|
100
|
35
|
.03556
|
17.07
|
2.05
|
|
90
|
35
|
.02501
|
12.00
|
1.44
|
|
80
|
35
|
.01698
|
8.149
|
.98
|
Standard Instrument Panels
|
|
A
|
B
|
C
|
D
|
E
|
F
|
|
On/Off Switch/Light
|
|
X
|
X
|
X
|
X
|
X
|
|
Power On Light
|
X
|
|
|
|
|
|
|
High Temp Light
|
X
|
|
|
|
|
|
|
Refrigerant Suction Gauge
|
X
|
X
|
X
|
X
|
X
|
X
|
|
Air Inlet Temp Gauge
|
|
|
|
X
|
|
|
|
Discharge Pressure Gauge
|
|
|
|
|
|
X
|
|
Manual Drain Override
|
|
|
|
|
X
|
X
|
|
Drain Alarm Light
|
|
|
|
|
X
|
X
|
Voltage Codes
|
Code #
|
Standard
|
Export
|
|
1
|
115/1/60
|
100/1/50
|
|
2
|
208-230/1/60
|
200-240/1/50
|
|
3
|
208-230/3/60
|
200-240/3/50
|
|
4
|
460/3/60
|
380/3/50
|
|
5
|
575/3/60
|
|
|
Product Reviews
|
NEWS
-
Factory Direct Air Compressors
| |